ESA Automation EW600 The range of Esaware I/O modules

Update: 2016/5/26      View:
  • Brand:    ESA Automation
  • Type:    EW600
  • Order Online
Introduction

The range of Esaware I/O modules completes the HMI EW100AC series. Thanks to the EW600 I/O, now you have the ability to command and control all your applications.


Esaware I/O are modular, so it is possible to create different configurations as required. All I/O have been designed to guarantee excellent ergonomics and ease of installing. All I/O modules have a fast cabling system thanks to the cage clamps. In addition I/O modules can be cabled extracting the connectors. Esaware offers different kinds of I/O modules


Digital I/O – EW600B Mixed optoisolated input and output modules to prevent high voltages from affecting the system receiving the signal, transferring electrical signals between two isolated circuits by using light. Optoisolators give you complete control and command of your plant at any time. 

Digital I/O
EW600B08B04
 
Supply Voltage (Vdc) 24
Isolation Optoisolated
Input Number 8
Input Type PNP, NPN
Output Number 4
Output Type PNP ( 300 mA/output)
Protection Degree IP20
Operating Temperature (°C) -10 ... + 50 non condensing
Storage Temperature (°C) -20 ... + 65
Humidity <90% non condensing
External dimensions (mm) 96x72x20
Certifications CE / EN60068-2-6 / EN60068-2-27 / Humidity EN60068-2-30 / cULus (Certificate no. E189179) / EAC / Directive 94/9/EC Atex Group п – Category 3 G-D Zone 2/22 (Mounted on EW100AC)
Analog I/O
EW600A03A02
 
Supply Voltage (Vdc) 24
Input Number 3
Input Type 0/5 V, 0/10 V, +10/-10 V, 0/20 mA, 4/20 mA
Output Number 2
Output Type 0/5 V, 0/10 V, +10/-10 V, 0/20 mA, 4/20 mA
Resolution 16 Bit
Protection Degree IP20
Operating Temperature (°C) -10 ... + 50 (non condensing)
Storage Temperature (°C) -20 ... + 65
Humidity <90% (non condensing)
External dimensions (mm) 96x72x20
Certifications CE / EN60068-2-6 / EN60068-2-27 / Humidity EN60068-2-30 / cULus (Certificate no. E189179) / EAC / Directive 94/9/EC Atex Group п – Category 3 G-D Zone 2/22 (Mounted on EW100AC)

THERMOCOUPLE INPUT
EW600D06N00
 
Input Numbers 6
Input Type K / J / E / T / N / B / R / S
Resolution (°C) +0,1° / - 0,1°
Cold Junction Internal and External
Operating Temperature (°C) -10 … + 50 non condensing
Storage Temperature (°C) -20 … + 65
Humidity <90% non condensing
External dimensions (W/H/D) (mm) 96 x 72 x 20
Protection Degree IP 20
Certifications CE / EN60068-2-6 / EN60068-2-27 / Humidity EN60068-2-30 / cULus (Certificate no. E189179) / EAC/ Directive 94/9/EC Atex Group п – Category 3 G-D Zone 2/22 (Mounted on EW100AC)