reliability and maximum process
availability
Rosemount Reliability -The 8800D Vortex eliminates
impulse lines, ports, and gaskets to improve reliability.
Non-clog Design - Unique all welded, gasket-free
construction which has no ports or crevices that can clog.
Vibration Immunity - Mass balancing of the sensor system,
and Adaptive Digital Signal Processing (ADSP) provide
vibration immunity.
Replaceable Sensor - The sensor is isolated from the
process and can be replaced without breaking the process
seal. All line sizes use the same sensor design allowing a
single spare to serve every meter.
Simplified Troubleshooting - Device Diagnostics enable
field verification of meter electronics and sensor without
process shutdown.
The Rosemount 8800D Offering
The 8800D is available in wafer style meter bodies for 1/2
through 8-in. line sizes, and ASME B16.5, EN 1092-1, or JIS
B2220 flanged style meter bodies for 1/2 through 12-in. line
sizes.
Alignment rings, provided with each wafer-style
flowmeter,27 ensure that the meter body is properly
centered with the adjacent piping.
The wafer, flanged, and weld end style meter bodies are
available in 316 stainless steel and nickel alloy materials of
construction.
Available up to ASME B16.5 class 1500 for 1 through 8-in.
(25 mm through 200 mm) line sizes.
Available with FOUNDATION fieldbus functionality
which includes Device Diagnostics and PlantWeb
Alerts.
Ordering Information
Table 1. Rosemount 8800D Vortex Flowmeter
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model Product Description
8800D Vortex Flowmeter
Meter Style
Standard Standard
F Flanged style ★
W Wafer style ★
R Reducer Style (Flanged style only) ★
Expanded
D Dual-sensor style (Flanged style only)
Line Size
Standard Standard
005 1/2-in. (15 mm) (Not available for Rosemount 8800DR) ★
010 1-in. (25 mm) ★
015 11/2-in. (40 mm) ★
020 2-in. (50 mm) ★
030 3-in. (80 mm) ★
040 4-in. (100 mm) ★
060 6-in. (150 mm) ★
080 8-in. (200 mm) ★
Expanded
100 10-in. (250mm)
120 12-in. (300mm)
Wetted Materials
Standard Standard
S 316 wrought stainless and CF-3M cast stainless
Note: Material of construction is 316/316L
★
Expanded
H UNS N06022 wrought Nickel Alloy; CW2M cast Nickel Alloy
Note: See Table 2
Other wetted materials are available. Consult factory for details.
Flange or Alignment Ring Size
Standard Standard
A1 ASME B16.5 (ANSI) RF Class 150 ★
A3 ASME B16.5 (ANSI) RF Class 300 ★
K1 EN 1092-1 PN 16 (PN 10/16 for wafer style) Type B1 ★
K3 EN 1092-1 PN 40 (PN 25/40 for wafer style) Type B1 ★
Expanded
A6 ASME B16.5 (ANSI) RF Class 600
A7(1) ASME B16.5 (ANSI) RF Class 900
A8(2) ASME B16.5 (ANSI) RF Class 1500
B1(3) ASME B16.5 (ANSI) RTJ Class 150 for flange-style only
B3 ASME B16.5 (ANSI) RTJ Class 300 for flange-style only
B6 ASME B16.5 (ANSI) RTJ Class 600 for flange-style only
B7(1) ASME B16.5 (ANSI) RTJ Class 900 for flange-style only
B8(2) ASME B16.5 (ANSI) RTJ Class 1500 for flange-style only
C1 ASME B16.5 (ANSI) RF Class 150, smooth finish
C3 ASME B16.5 (ANSI) RF Class 300, smooth finish
C6 ASME B16.5 (ANSI) RF Class 600, smooth finish
Expanded
C7(1) ASME B16.5 (ANSI) RF Class 900, smooth finish
C8(2) ASME B16.5 (ANSI) RF Class 1500, smooth finish
K0 EN 1092-1 PN 10 Type B1
K2 EN 1092-1 PN 25 Type B1
K4 EN 1092-1 PN 63 Type B1
K6 EN 1092-1 PN 100 Type B1
K7(1) EN 1092-1 PN 160 Type B1
L0 EN 1092-1 PN 10 Type B2
L1 EN 1092-1 PN 16 (PN 10/16 for wafer style) Type B2
L2 EN 1092-1 PN 25 Type B2
L3 EN 1092-1 PN 40 (PN 25/40 for wafer style) Type B2
L4 EN 1092-1 PN 63 Type B2
L6 EN 1092-1 PN 100 Type B2
L7(1) EN 1092-1 PN 160 Type B2
M0 EN 1092-1 PN 10 Type D for flange style only
M1 EN 1092-1 PN 16 Type D for flange style only
M2 EN 1092-1 PN 25 Type D for flange style only
M3 EN 1092-1 PN 40 Type D for flange style only
M4 EN 1092-1 PN 63 Type D for flange style only
M6 EN 1092-1 PN 100 Type D for flange style only
M7(1) EN 1092-1 PN 160 Type D for flange style only
J1 JIS 10K
J2 JIS 20K
J4 JIS 40K
W1(4) Weld End, Schedule 10S
W4(4) Weld End, Schedule 40S
W8(4) Weld End, Schedule 80S
W9(3)(4) Weld End, Schedule 160S
Sensor Process Temperature Range
Standard Standard
N Standard: -40 to 450°F (-40 to 232°C) ★
E Extended: -330 to 800°F (-200 to 427°C) ★
Expanded
S Severe Service: -330 to 800 °F (-200 to 427 °C)
Conduit Entry
Standard Standard
1 1/2 -14 NPT – Aluminum Housing ★
2 M20 1.5 – Aluminum Housing ★
4 G1/2 (One Conduit Entry) – Aluminum Housing ★
5 G1/2 (Two Conduit Entries) – Aluminum Housing ★
Expanded
6(5) 1/2 - 14 NPT - SST Housing
7(5) M20 x 1.5 - SST Housing
Outputs
Standard Standard
D 4-20 mA digital electronics (HART protocol) ★
P 4-20 mA digital electronics (HART protocol) with scaled pulse ★
F FOUNDATION fieldbus digital signal
Calibration
Standard Standard
1 Flow calibration ★
Options
MultiVariable Options
Expanded
MTA(6) MultiVariable output with Integral Temperature Sensor
Hazardous Locations Certifications
Standard Standard
E5 FM Explosion-proof; Dust Ignition-proof ★
I5 FM Intrinsically Safe; Non-incendive ★
IE(7) FM FISCO Intrinsically Safe ★
K5 FM Explosion-proof; Intrinsically Safe; Non-incendive; Dust Ignition-proof ★
E6 CSA Explosion-proof; Division 2 Dust Ignition-proof ★
I6 CSA Intrinsically Safe ★
IF(7) CSA FISCO Intrinsically Safe ★
K6 CSA Explosion-proof; Intrinsically Safe; Division 2; Dust-Ignition-proof ★
KB FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Non-incendive ★
E1 ATEX Flameproof ★
I1 ATEX Intrinsic Safety ia; Intrinsic Safety ic ★
IA(7) ATEX FISCO Intrinsic Safety ★
N1 ATEX Type n ★
ND ATEX Dust ★
K1 ATEX Flameproof; Intrinsic Safety; Type n; Dust ★
E7 IECEx Flameproof ★
I7 IECEx Intrinsic Safety ★
IG(7) IECEx FISCO Intrinsic Safety ★
N7 IECEx Type n ★
K7 IECEx Flameproof; Intrinsic Safety; Type n; Dust ★
E2 INMETRO Flameproof ★
I2 INMETRO Intrinsic Safety ★
E3 China Flameproof; Dust ★
I3 China Intrinsic Safety ★
N3 China Type n ★
IH(7) China FISCO/FNICO Intrinsic Safety ★
K3 China Flameproof; Dust; Intrinsic Safety; Type n ★
E4(8) TIIS Flameproof ★
IB(7) INMETRO FISCO Intrinsic Safety ★
Plantweb Control Functionality
Standard Standard
A01(9) Basic Control: One Proportional/Integral/Derivative (PID) Function Block ★
Conduit Electrical Connector
Expanded
GE(10) M12, 4-pin, Male Connector (eurofast®)
GM(10) A size Mini, 4-pin, Male Connector (minifast®)
GN ATEX Flameproof A size, Mini 4-pin male connector (minifast)