In stock
|
1-channel isolated barrier, 24 V DC supply (loop powered), Current or voltage input, Output: 4 ... 20 mA, Potentiometer or DIP switch selectable ranges, Line fault detection (LFD), Input: Current/voltage, Rated voltage: 12 ... 35 V DC loop powered, Output: 4-20 mA
|
|
|
-
KFD2-PT2-Ex1
-
Potentiometer Converter
-
|
In stock
|
1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 10 V, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL2 acc. to IEC 61508, Input: Resistance, Rated voltage: 20 ... 35 V DC, Output: 0-10 V, SIL/IEC 61508
|
|
|
-
KFD2-PT2-Ex1-5
-
Potentiometer Converter
-
|
In stock
|
1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Current output 4 mA ... 20 mA, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL2 acc. to IEC 61508, Input: Resistance, Rated voltage: 20 ... 35 V DC, Output: 4-20 mA, SIL/IEC 61508
|
|
|
|
Contact Us
|
2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: Temperature, Rated voltage: 20 ... 30 V DC, Output: 4-20 mA
|
|
|
-
KFD2-WAC2-Ex1.D
-
Strain Gauge Converter
-
|
In stock
|
1-channel isolated barrier, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA ... ± 20 mA or 0 V ... ± 10 V, Relay contact output, Programmable high/low alarm, Configurable by PACTware or keypad, RS 485 interface, Line fault detection (LFD), Input: DMS bridges, Rated voltage: 20 ... 35 V DC, Output: 4-20 mA
|
|
|
|
Contact Us
|
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Input: Temperature, Rated voltage: 19 ... 30 V DC, Output: 4-20 mA
|
|
|
-
KFD0-TR-Ex1
-
RTD Converter
-
|
Contact Us
|
1-channel isolated barrier, 24 V DC supply (loop powered), 2- or 3-wire Pt100 RTD input, Output 4 mA ... 20 mA, temperature linearization selectable, DIP switch selectable ranges, Sensor breakage detection, Input: Resistance, Rated voltage: 12 ... 35 V DC loop powered, Output: 4-20 mA
|
|
|
-
KFD0-TT-Ex1
-
Thermocouple Converter
-
|
Contact Us
|
1-channel isolated barrier, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA ... 20 mA, Internal cold junction compensation, Sensor breakage detection, DIP switch selectable ranges, Input: Thermocouple, Rated voltage: 12 ... 35 V DC loop powered, Output: 4-20 mA
|
|
|
|
Contact Us
|
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL2 acc. to IEC 61508/IEC 61511, Input: Temperature, Rated voltage: 20 ... 30 V DC, Output: 2 x 1 changeover contact + 4-20 mA, SIL/IEC 61508
|
|
|
-
KFD2-PT2-Ex1-1
-
Potentiometer Converter
-
|
Contact Us
|
1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 5 V, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL2 acc. to IEC 61508, Input: Resistance, Rated voltage: 20 ... 35 V DC, Output: 0-5 V, SIL/IEC 61508
|
|