PEPPERL+FUCHS Transmitter Power Supplies

Update: 2016/5/27      View:
  • Brand:    PEPPERL+FUCHS
  • Type:    KFD2-STC4-Ex2
  • Order Online
Introduction


In stock

1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Housing width 12.5 mm, Up to SIL2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 19 ... 30 V DC, SIL/IEC 61508


Contact Us

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: 2-wire transmitter|3-wire transmitter, Rated voltage: 20 ... 30 V DC, Output: 2 x 1 changeover contact + 4-20 mA, SIL/IEC 61508


In stock

1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input (revision 5 to 7) with transmitter power supply, Usable as signal splitter (1 input and multiple outputs), 3 analog outputs 4 mA ... 20 mA, Sink and source mode output, Configurable by keypad
USD69.00

In Fulltech stock

1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA, Terminals with test points, Up to SIL2 acc. to IEC 61508, Input: 2-wire transmitter|3-wire transmitter, Rated voltage: 20 ... 35 V DC, SIL/IEC 61508


In ulltech stock

2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/4 mA ... 20 mA, Terminals with test points, Up to SIL2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 20 ... 35 V DC, SIL/IEC 61508
 Contact Us
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 18 ... 30 V DC, SIL/IEC 61508
 Contact Us
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 18 ... 30 V DC, SIL/IEC 61508
 Contact Us
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL3 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 19 ... 30 V DC, SIL/IEC 61508
 Contact Us
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals, Up to SIL3 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 19 ... 30 V DC, SIL/IEC 61508
 Contact Us
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Low power dissipation, Suitable for long field cables (> 1000 m), Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 19 ... 30 V DC, SIL/IEC 61508
More Products