Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: 2-wire transmitter|3-wire transmitter, Rated voltage: 20 ... 30 V DC, Output: 2 x 1 changeover contact + 4-20 mA, SIL/IEC 61508
|
|
|
-
KFD2-WAC2-Ex1.D
-
Strain Gauge Converter
-
|
In stock
|
1-channel isolated barrier, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA ... ± 20 mA or 0 V ... ± 10 V, Relay contact output, Programmable high/low alarm, Configurable by PACTware or keypad, RS 485 interface, Line fault detection (LFD), Input: DMS bridges, Rated voltage: 20 ... 35 V DC, Output: 4-20 mA
|
|
|
|
Contact Us
|
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, voltage or current input, 2 relay contact outputs, Programmable high/low alarm, Configurable by PACTware, Sensor breakage detection, Input: Temperature, Rated voltage: 19 ... 35 V DC, Output: 2 x 1 changeover contact
|
|
|
|
Contact Us
|
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL2 acc. to IEC 61508/IEC 61511, Input: Temperature, Rated voltage: 20 ... 30 V DC, Output: 2 x 1 changeover contact + 4-20 mA, SIL/IEC 61508
|
|
|
-
KFD2-WAC2-Ex1.D-Y1
-
Strain Gauge Converter
-
|
Contact Us
|
1-channel isolated barrier, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA ... ± 20 mA or 0 V ... ± 10 V, Relay contact output, Programmable high/low alarm, Configurable by PACTware or keypad, RS 485 interface, Low response time, Line fault detection (LFD), Input: DMS bridges, Rated voltage: 20 ... 35 V DC, Output: 4-20 mA
|
|
|
-
KFU8-CRG2-Ex1.D
-
Transmitter Power Supply
-
|
Contact Us
|
1-channel isolated barrier, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: 2-wire transmitter|3-wire transmitter, Rated voltage: 20 ... 90 V DC or 48 ... 253 V AC, Output: 2 x 1 changeover contact + 4-20 mA
|
|
|
|
Contact Us
|
1-channel isolated barrier, Universal usage at different power supplies, Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL2 acc. to IEC 61508/IEC 61511, Input: Temperature, Rated voltage: 20 ... 90 V DC / 48 ... 253 V AC, Output: 2 x 1 changeover contact + 4-20 mA, SIL/IEC 61508
|
|