The flowmeter for highest medium temperatures with a modular electronic concept
Promag P is the preferred sensor for applications with highest requirements in a multitude of industries. Combined with the proven Promag 50 transmitter with push buttons, Promag 50P offers highly accurate measurement of liquids for a wide range of applications. Promag 50P is dedicated for chemical and process applications with corrosive liquids and high medium temperatures. Promag 50P is available in a compact or remote version.
Benefits
-
Versatile applications – wide variety of wetted materials
-
Energy-saving flow measurement – no pressure loss due to cross-section constriction
-
Fast commissioning – application-specific Quick Setups
-
Safe operation – display provides easy readable process information
-
Fully industry compliant – IEC/EN/NAMUR
Field of application
-
The measuring principle is virtually independent of pressure, density, temperature and viscosity
-
Dedicated for chemical and process applications with corrosive liquids and high medium temperatures.
Device properties
-
Nominal diameter: max. DN 600 (24")
-
All common Ex approvals
-
Liner made of PTFE or PFA
-
2-line display with push buttons
-
Device in compact or remote version
-
HART, PROFIBUS PA/DP
| Measuring Principle | Electromagnetic | |
| Product headline |
The flowmeter for highest medium temperatures with a modular electronic concept. Dedicated for chemical and process applications with corrosive liquids and high medium temperatures. |
|
| Sensor features |
Versatile applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance‐free – no moving parts. Nominal diameter: max. DN 600 (24"). All common Ex approvals. |
|
| Transmitter features |
Fast commissioning – application‐specific Quick Setups. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version. |
|
| Nominal diameter range |
DN 15...600 1/2"...24" |
|
| Max. measured error |
±0.5% ±0.2% (optional) |
|
| Measuring range |
0...9'600 m3/h |
|
| Max. process pressure |
PN10...40 Cl 150...300 JIS 10...20K AS 2129 Table E AS 4087 PN16 |
|
| Medium temperature range |
-40...+180°C (-40...+356°F) |
|
| Ambient temperature range |
-20...+60°C -40...+60°C (optional) |
|
| Degree of protection |
IP 67 (NEMA 4x) IP 68 (Nema 6P) |
|
| Display/Operation |
Two line display with backlit Push button |
|
| Outputs |
4...20 mA Pulse/Frequency Status |
|
| Inputs |
Status |
|
| Digital communication |
HART PROFIBUS PA |
|
| Hazardous area approvals |
ATEX FM CSA TIIS |
|