										 In stock |  
							| 1-channel isolated barrier, 24 V DC supply (loop powered), Current or voltage input, Output: 4 ... 20 mA, Potentiometer or DIP switch selectable ranges, Line fault detection (LFD), Input: Current/voltage, Rated voltage: 12 ... 35 V DC loop powered, Output: 4-20 mA |  | 
		
			| 
					
						
							|   | 
									
										KFD2-PT2-Ex1
									
										
											Potentiometer Converter
										
									 | 
									
 
									
										 In stock |  
							| 1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 10 V, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL2 acc. to IEC 61508, Input: Resistance, Rated voltage: 20 ... 35 V DC, Output: 0-10 V, SIL/IEC 61508 |  | 
		
			| 
					
						
							|   | 
									
										KFD2-PT2-Ex1-5
									
										
											Potentiometer Converter
										
									 | 
									
 
									
									
										 In stock |  
							| 1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Current output 4 mA ... 20 mA, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL2 acc. to IEC 61508, Input: Resistance, Rated voltage: 20 ... 35 V DC, Output: 4-20 mA, SIL/IEC 61508 |  | 
		
			| 
					
						
							|   |  | 
									
 
									
									
										 Contact Us |  
							| 2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: Temperature, Rated voltage: 20 ... 30 V DC, Output: 4-20 mA |  | 
		
			| 
					
						
							|   | 
									
										KFD2-WAC2-Ex1.D
									
										
											Strain Gauge Converter
										
									 | 
									
 
									
									
										 In stock |  
							| 1-channel isolated barrier, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA ... ± 20 mA or 0 V ... ± 10 V, Relay contact output, Programmable high/low alarm, Configurable by PACTware or keypad, RS 485 interface, Line fault detection (LFD), Input: DMS bridges, Rated voltage: 20 ... 35 V DC, Output: 4-20 mA |  | 
		
			| 
					
						
							|   |  | 
								 
									  Contact Us
								 |  
							| 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Input: Temperature, Rated voltage: 19 ... 30 V DC, Output: 4-20 mA |  | 
		
			| 
					
						
							|   | 
									
										KFD0-TR-Ex1
									
										
											RTD Converter
										
									 | 
								 
									  Contact Us
								 |  
							| 1-channel isolated barrier, 24 V DC supply (loop powered), 2- or 3-wire Pt100 RTD input, Output 4 mA ... 20 mA, temperature linearization selectable, DIP switch selectable ranges, Sensor breakage detection, Input: Resistance, Rated voltage: 12 ... 35 V DC loop powered, Output: 4-20 mA |  | 
		
			| 
					
						
							|   | 
									
										KFD0-TT-Ex1
									
										
											Thermocouple Converter
										
									 | 
								 
									  Contact Us
								 |  
							| 1-channel isolated barrier, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA ... 20 mA, Internal cold junction compensation, Sensor breakage detection, DIP switch selectable ranges, Input: Thermocouple, Rated voltage: 12 ... 35 V DC loop powered, Output: 4-20 mA |  | 
		
			| 
					
						
							|   |  | 
								 
									  Contact Us
								 |  
							| 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL2 acc. to IEC 61508/IEC 61511, Input: Temperature, Rated voltage: 20 ... 30 V DC, Output: 2 x 1 changeover contact + 4-20 mA, SIL/IEC 61508 |  | 
		
			| 
					
						
							|   | 
									
										KFD2-PT2-Ex1-1
									
										
											Potentiometer Converter
										
									 | 
								 
									  Contact Us
								 |  
							| 1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 5 V, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL2 acc. to IEC 61508, Input: Resistance, Rated voltage: 20 ... 35 V DC, Output: 0-5 V, SIL/IEC 61508 |  |