										KFD2-CRG2-Ex1.D
									
										
											Transmitter Power Supply
										
									 | 
									
 
									
									
										 Contact Us |  
							| 1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: 2-wire transmitter|3-wire transmitter, Rated voltage: 20 ... 30 V DC, Output: 2 x 1 changeover contact + 4-20 mA, SIL/IEC 61508 |  | 
		
			| 
					
						
							|   | 
									
										KFD2-WAC2-Ex1.D
									
										
											Strain Gauge Converter
										
									 | 
									
 
									
									
										 In stock |  
							| 1-channel isolated barrier, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA ... ± 20 mA or 0 V ... ± 10 V, Relay contact output, Programmable high/low alarm, Configurable by PACTware or keypad, RS 485 interface, Line fault detection (LFD), Input: DMS bridges, Rated voltage: 20 ... 35 V DC, Output: 4-20 mA |  | 
		
			| 
					
						
							|   |  | 
								 
									  Contact Us
								 |  
							| 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, voltage or current input, 2 relay contact outputs, Programmable high/low alarm, Configurable by PACTware, Sensor breakage detection, Input: Temperature, Rated voltage: 19 ... 35 V DC, Output: 2 x 1 changeover contact |  | 
		
			| 
					
						
							|   |  | 
								 
									  Contact Us
								 |  
							| 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL2 acc. to IEC 61508/IEC 61511, Input: Temperature, Rated voltage: 20 ... 30 V DC, Output: 2 x 1 changeover contact + 4-20 mA, SIL/IEC 61508 |  | 
		
			| 
					
						
							|   | 
									
										KFD2-WAC2-Ex1.D-Y1
									
										
											Strain Gauge Converter
										
									 | 
								 
									  Contact Us
								 |  
							| 1-channel isolated barrier, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA ... ± 20 mA or 0 V ... ± 10 V, Relay contact output, Programmable high/low alarm, Configurable by PACTware or keypad, RS 485 interface, Low response time, Line fault detection (LFD), Input: DMS bridges, Rated voltage: 20 ... 35 V DC, Output: 4-20 mA |  | 
		
			| 
					
						
							|   | 
									
										KFU8-CRG2-Ex1.D
									
										
											Transmitter Power Supply
										
									 | 
								 
									  Contact Us
								 |  
							| 1-channel isolated barrier, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: 2-wire transmitter|3-wire transmitter, Rated voltage: 20 ... 90 V DC or 48 ... 253 V AC, Output: 2 x 1 changeover contact + 4-20 mA |  | 
		
			| 
					
						
							|   |  | 
								 
									  Contact Us
								 |  
							| 1-channel isolated barrier, Universal usage at different power supplies, Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL2 acc. to IEC 61508/IEC 61511, Input: Temperature, Rated voltage: 20 ... 90 V DC / 48 ... 253 V AC, Output: 2 x 1 changeover contact + 4-20 mA, SIL/IEC 61508 |  |